FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.4.11  |  FHIR Version n/a  User: [n/a]

Resource Requirements/FHIR Server from package hl7.ehrs.ehrsfmr21#current (31 ms)

Package hl7.ehrs.ehrsfmr21
Type Requirements
Id Id
FHIR Version R5
Source http://hl7.org/ehrs/https://build.fhir.org/ig/mvdzel/ehrsfm-fhir-r5/Requirements-EHRSFMR2.1-RI.1.1.8.html
Url http://hl7.org/ehrs/Requirements/EHRSFMR2.1-RI.1.1.8
Version 2.1.0
Status active
Date 2024-11-26T16:30:50+00:00
Name RI_1_1_8_Transmit_Record_Lifecycle_Event
Title RI.1.1.8 Transmit Record Lifecycle Event (Function)
Experimental False
Realm uv
Authority hl7
Description Transmit Record Entries (1 or more instances)
Purpose Occurs when an agent causes the system to send record entry content from one (EHR/PHR/other) system to another. Reference: ISO 21089-2018, Section 15.8.

Resources that use this resource

No resources found


Resources that this resource uses

No resources found



Narrative

Note: links and images are rebased to the (stated) source

Statement N:

Transmit Record Entries (1 or more instances)

Description I:

Occurs when an agent causes the system to send record entry content from one (EHR/PHR/other) system to another.

Reference: ISO 21089-2018, Section 15.8.

Criteria N:
RI.1.1.8#01 SHOULD

The system SHOULD provide the ability to transmit Record Entry content to external systems, retaining original, unaltered content and signature bindings, Action and Record Entry provenance and metadata.

RI.1.1.8#02 SHALL

The system SHALL provide the ability to transmit Record Entry extracts to external systems, including content, context, provenance and metadata.

RI.1.1.8#03 SHALL

The system SHALL provide the ability to capture the identity of the patient or individual subject to whom Record Entry content was transmitted.

RI.1.1.8#04 dependent conditional SHOULD

IF a specific recipient is known, THEN the system SHOULD transmit protected Record Entry content based on established permissions and according to scope of practice, organizational policy, and/or jurisdictional law.

RI.1.1.8#05 conditional SHOULD

IF known and explicit as to Record Entry content being transmitted, THEN the system SHOULD transmit corresponding authorizations and patient consent permissions.

RI.1.1.8#06 SHALL

The system SHALL conform to function [[TI.1.6]] (Secure Data Exchange).

RI.1.1.8#07 SHALL

The system SHALL provide the ability to extract Record Entry content prior to transmittal, conforming to function [[RI.1.1.13]] (Extract Record Entry Content).

RI.1.1.8#08 SHALL

The system SHALL provide the ability to de-identify Record Entry content prior to transmittal, conforming to function [[RI.1.1.10]] (De-Identify Record Entries).

RI.1.1.8#09 dependent SHALL

The system SHALL provide the ability to transmit updates (new versions) of Record Entry Content to known recipients of prior versions according to scope of practice, organizational policy, and/or jurisdictional law.

RI.1.1.8#10 dependent SHALL

The system SHALL provide the ability to transmit with each exchange the most recent or all versions of Record Entry Content according to scope of practice, organizational policy, and/or jurisdictional law.


Source

{
  "resourceType" : "Requirements",
  "id" : "EHRSFMR2.1-RI.1.1.8",
  "meta" : {
    "profile" : [
      "http://hl7.org/ehrs/StructureDefinition/FMFunction"
    ]
  },
  "text" : {
    "status" : "extensions",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n <span id=\"description\"><b>Statement <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Normative Content\" class=\"normative-flag\">N</a>:</b> <div><p>Transmit Record Entries (1 or more instances)</p>\n</div></span>\n\n \n <span id=\"purpose\"><b>Description <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Informative Content\" class=\"informative-flag\">I</a>:</b> <div><p>Occurs when an agent causes the system to send record entry content from one (EHR/PHR/other) system to another.</p>\n<p>Reference: ISO 21089-2018, Section 15.8.</p>\n</div></span>\n \n\n \n\n \n <span id=\"requirements\"><b>Criteria <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Normative Content\" class=\"normative-flag\">N</a>:</b></span>\n \n <table id=\"statements\" class=\"grid dict\">\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.8#01</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHOULD</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHOULD provide the ability to transmit Record Entry content to external systems, retaining original, unaltered content and signature bindings, Action and Record Entry provenance and metadata.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.8#02</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL provide the ability to transmit Record Entry extracts to external systems, including content, context, provenance and metadata.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.8#03</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL provide the ability to capture the identity of the patient or individual subject to whom Record Entry content was transmitted.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.8#04</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n <i>dependent</i>\n \n \n <i>conditional</i>\n \n \n <span>SHOULD</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>IF a specific recipient is known, THEN the system SHOULD transmit protected Record Entry content based on established permissions and according to scope of practice, organizational policy, and/or jurisdictional law.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.8#05</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n <i>conditional</i>\n \n \n <span>SHOULD</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>IF known and explicit as to Record Entry content being transmitted, THEN the system SHOULD transmit corresponding authorizations and patient consent permissions.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.8#06</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL conform to function [[TI.1.6]] (Secure Data Exchange).</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.8#07</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL provide the ability to extract Record Entry content prior to transmittal, conforming to function [[RI.1.1.13]] (Extract Record Entry Content).</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.8#08</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL provide the ability to de-identify Record Entry content prior to transmittal, conforming to function [[RI.1.1.10]] (De-Identify Record Entries).</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.8#09</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n <i>dependent</i>\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL provide the ability to transmit updates (new versions) of Record Entry Content to known recipients of prior versions according to scope of practice, organizational policy, and/or jurisdictional law.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.8#10</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n <i>dependent</i>\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL provide the ability to transmit with each exchange the most recent or all versions of Record Entry Content according to scope of practice, organizational policy, and/or jurisdictional law.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n </table>\n</div>"
  },
  "url" : "http://hl7.org/ehrs/Requirements/EHRSFMR2.1-RI.1.1.8",
  "version" : "2.1.0",
  "name" : "RI_1_1_8_Transmit_Record_Lifecycle_Event",
  "title" : "RI.1.1.8 Transmit Record Lifecycle Event (Function)",
  "status" : "active",
  "date" : "2024-11-26T16:30:50+00:00",
  "publisher" : "EHR WG",
  "contact" : [
    {
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/ehr"
        }
      ]
    }
  ],
  "description" : "Transmit Record Entries (1 or more instances)",
  "jurisdiction" : [
    {
      "coding" : [
        {
          "system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code" : "001",
          "display" : "World"
        }
      ]
    }
  ],
  "purpose" : "Occurs when an agent causes the system to send record entry content from one (EHR/PHR/other) system to another. \n\nReference: ISO 21089-2018, Section 15.8.",
  "statement" : [
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8-01",
      "label" : "RI.1.1.8#01",
      "conformance" : [
        "SHOULD"
      ],
      "conditionality" : false,
      "requirement" : "The system SHOULD provide the ability to transmit Record Entry content to external systems, retaining original, unaltered content and signature bindings, Action and Record Entry provenance and metadata."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8-02",
      "label" : "RI.1.1.8#02",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL provide the ability to transmit Record Entry extracts to external systems, including content, context, provenance and metadata."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8-03",
      "label" : "RI.1.1.8#03",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL provide the ability to capture the identity of the patient or individual subject to whom Record Entry content was transmitted."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : true
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8-04",
      "label" : "RI.1.1.8#04",
      "conformance" : [
        "SHOULD"
      ],
      "conditionality" : true,
      "requirement" : "IF a specific recipient is known, THEN the system SHOULD transmit protected Record Entry content based on established permissions and according to scope of practice, organizational policy, and/or jurisdictional law."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8-05",
      "label" : "RI.1.1.8#05",
      "conformance" : [
        "SHOULD"
      ],
      "conditionality" : true,
      "requirement" : "IF known and explicit as to Record Entry content being transmitted, THEN the system SHOULD transmit corresponding authorizations and patient consent permissions."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8-06",
      "label" : "RI.1.1.8#06",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL conform to function [[TI.1.6]] (Secure Data Exchange)."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8-07",
      "label" : "RI.1.1.8#07",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL provide the ability to extract Record Entry content prior to transmittal, conforming to function [[RI.1.1.13]] (Extract Record Entry Content)."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8-08",
      "label" : "RI.1.1.8#08",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL provide the ability to de-identify Record Entry content prior to transmittal, conforming to function [[RI.1.1.10]] (De-Identify Record Entries)."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : true
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8-09",
      "label" : "RI.1.1.8#09",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL provide the ability to transmit updates (new versions) of Record Entry Content to known recipients of prior versions according to scope of practice, organizational policy, and/or jurisdictional law."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : true
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8-10",
      "label" : "RI.1.1.8#10",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL provide the ability to transmit with each exchange the most recent or all versions of Record Entry Content according to scope of practice, organizational policy, and/or jurisdictional law."
    }
  ]
}

XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.